2024-02-08 22:00:00.004921 INFO pred_bat: --------------- PredBat - update at 2024-02-08 22:00:00.004060+01:00 with clock skew 0 minutes, minutes now 1320
2024-02-08 22:00:00.005915 INFO pred_bat: Using cached GITHub data for https://api.github.com/repos/springfall2008/batpred/releases age 14.2 minutes
2024-02-08 22:00:00.006895 INFO pred_bat: Predbat /config/apps/predbat.py version v7.15.17 currently running, latest version is v7.15.17 latest beta v7.15.17
2024-02-08 22:00:00.007892 INFO pred_bat: Autoupdate: Currently up to date
2024-02-08 22:00:00.066552 INFO pred_bat: Inverter type HU forecast_hours 48 max_windows 48 num_cars 0 debug enable is False calculate_plan_every 10
2024-02-08 22:00:00.068001 INFO pred_bat: WARN: Using experimental inverter type HU - not all features are available
2024-02-08 22:00:00.069369 INFO pred_bat: Predbat mode is set to Control charge & discharge
2024-02-08 22:00:00.701382 INFO pred_bat: Found 11521 load_today datapoints going back 8 days
2024-02-08 22:00:02.183714 INFO pred_bat: Car charging hold False threshold 6.0
2024-02-08 22:00:02.184623 INFO pred_bat: Current data so far today: load 11.92 kWh import 49.43 kWh export 0.25 kWh pv 16.98 kWh
2024-02-08 22:00:02.185507 INFO pred_bat: Fetching futurerate data from None
2024-02-08 22:00:02.191132 INFO pred_bat: Standing charge is set to 0.0 p
2024-02-08 22:00:02.562798 INFO pred_bat: Rate min forward looking: now 93.1 at end of forecast 93.1
2024-02-08 22:00:02.564313 INFO pred_bat: Import rates min 93.1 max 187.9 average 125.06
2024-02-08 22:00:02.573046 INFO pred_bat: Export rates min 74.0 max 150.0 average 99.96
2024-02-08 22:00:02.574547 INFO pred_bat: Rate thresholds (for charge/discharge) are import 187.4p (0.0) export 74.5p (0.0)
2024-02-08 22:00:02.585219 INFO pred_bat: High export rate found rates in range 80.0 to 150.0
2024-02-08 22:00:02.595336 INFO pred_bat: Low Import rate found rates in range 93.1 to 160.2
2024-02-08 22:00:02.623580 INFO pred_bat: Todays energy import 49.43 kWh export 0.25 kWh cost 5920.46 p import 5946.75 p export -26.29 p
2024-02-08 22:00:02.628814 INFO pred_bat: PV Data for pv_forecast_today total 0.05 kWh
2024-02-08 22:00:02.631899 INFO pred_bat: PV Data for pv_forecast_tomorrow total 0.26 kWh
2024-02-08 22:00:02.635047 INFO pred_bat: PV Data for pv_forecast_d3 total 0.1 kWh
2024-02-08 22:00:02.638227 INFO pred_bat: PV Data for pv_forecast_d4 total 0.19 kWh
2024-02-08 22:00:02.649193 INFO pred_bat: Historical data totals for days [7] are [11.9] - min 11.9
2024-02-08 22:00:02.650924 INFO pred_bat: WARN: Historical day 7 has 615 minutes of gap in the data, filled from 11.9 kWh to make new average 20.77 kWh (percent 57%)
2024-02-08 22:00:02.687257 INFO pred_bat: Historical days now [7] weight [1]
2024-02-08 22:00:02.695990 INFO pred_bat: Today's load divergence -29.79 % in-day adjustment 50.0 % damping 0.95x, Predicted so far 17.51 kWh with 0.0 kWh car excluded and 2.16 kWh import ignored and 0 forecast extra, Actual so far 7.53 kWh with 0.0 kWh car excluded and 4.39 kWh import ignored
2024-02-08 22:00:02.727409 INFO pred_bat: Reserve min: 4.0% Battery_min:4.0%
2024-02-08 22:00:02.728790 INFO pred_bat: Inverter 0 with soc_max 10.0 kWh nominal_capacity 10.0 kWh battery rate raw 2500.0 w charge rate 2.5 kW discharge rate 2.5 kW battery_rate_min 0.0 w ac limit 10.0 kW export limit 10.0 kW reserve 4.0 % current_reserve 4.0 %
2024-02-08 22:00:02.733369 INFO pred_bat: Inverter 0 SOC: 0.3 kW 3 % Current charge rate 2500.0 w Current discharge rate 2500.0 w Current power 0.0 w Current voltage 52.0
2024-02-08 22:00:02.734408 INFO pred_bat: Inverter 0 scheduled charge enable is False
2024-02-08 22:00:02.735472 INFO pred_bat: Inverter 0 charge windows currently []
2024-02-08 22:00:02.736530 INFO pred_bat: Inverter 0 Charge settings: timed charged is disabled, power 2.5 kW
2024-02-08 22:00:02.738330 INFO pred_bat: Inverter 0 scheduled discharge enable is False
2024-02-08 22:00:02.739562 INFO pred_bat: Inverter 0 discharge windows currently [{'start': 0, 'end': 0, 'average': 0}, {'start': 1440, 'end': 1440, 'average': 0}]
2024-02-08 22:00:02.740324 INFO pred_bat: Note: Inverter does not support discharge freeze - disabled
2024-02-08 22:00:02.741073 INFO pred_bat: Note: Inverter does not support reserve - disabled
2024-02-08 22:00:02.741949 INFO pred_bat: Found 1 inverters totals: min reserve 0.4 current reserve 0.4 soc_max 10.0 soc 0.3 charge rate 2.5 kW discharge rate 2.5 kW battery_rate_min 0.0 w ac limit 10.0 export limit 10.0 kW loss charge 3 % loss discharge 3 % inverter loss 4 %
2024-02-08 22:00:02.768451 INFO pred_bat: Base charge window [ ]
2024-02-08 22:00:02.769443 INFO pred_bat: Base discharge window [ 08-02 00:00:00 - 08-02 00:00:00 @ 0p 100.0%, 09-02 00:00:00 - 09-02 00:00:00 @ 0p 100.0% ]
2024-02-08 22:00:02.770157 INFO pred_bat: Plan was last updated on 2024-02-08 21:55:00.006384+01:00 and is now 5.0 minutes old
2024-02-08 22:00:02.771108 INFO pred_bat: Best charge window [ 08-02 22:00:00 - 08-02 23:00:00 @ 106.7p 5%, 08-02 23:00:00 - 09-02 00:00:00 @ 93.1p 33%, 09-02 00:00:00 - 09-02 01:00:00 @ 104.0p 30%, 09-02 01:00:00 - 09-02 02:00:00 @ 103.3p 33%, 09-02 02:00:00 - 09-02 03:00:00 @ 101.8p 53%, 09-02 03:00:00 - 09-02 05:00:00 @ 100.25p 100%, 09-02 12:00:00 - 09-02 13:00:00 @ 126.1p 36%, 09-02 23:00:00 - 10-02 08:00:00 @ 93.1p 100%, 10-02 09:00:00 - 10-02 22:00:00 @ 160.2p 100% ]
2024-02-08 22:00:02.771949 INFO pred_bat: Best discharge window [ 09-02 08:25:00 - 09-02 09:00:00 @ 150.0p 57% ]
2024-02-08 22:00:02.803474 INFO pred_bat: predict base end_record 02-09 23:05:00 final soc 0.4 kWh metric 7773.7 p metric_keep 901.36 min_soc 0.4 @ 02-08 23:05:00 kWh load 25.04 pv 17.24
2024-02-08 22:00:02.805552 INFO pred_bat: [ 22:00, 23:00, 00:00, 01:00, 02:00, 03:00, 04:00, 05:00, 06:00, 07:00, 08:00, 09:00, 10:00, 11:00, 12:00, 13:00, 14:00, 15:00, 16:00, 17:00, 18:00, 19:00, 20:00, 21:00, 22:00, 23:00]
2024-02-08 22:00:02.807381 INFO pred_bat: SOC: [ 0.3, 0.43, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4]
2024-02-08 22:00:02.809207 INFO pred_bat: STATE: [ g<be-, g~be~, g~be~, g~be~, g~be~, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g~be+, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~]
2024-02-08 22:00:02.811080 INFO pred_bat: LOAD: [ 11.92, 12.05, 12.12, 12.27, 12.41, 12.56, 12.56, 12.57, 12.57, 12.58, 14.01, 15.95, 17.34, 19.48, 21.04, 22.45, 24.0, 24.13, 24.18, 24.32, 24.46, 24.61, 24.75, 24.9, 25.04, 25.04]
2024-02-08 22:00:02.812918 INFO pred_bat: PV: [ 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 17.0, 17.05, 17.1, 17.15, 17.19, 17.22, 17.23, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24]
2024-02-08 22:00:02.814763 INFO pred_bat: IMPORT: [ 49.43, 49.6, 49.65, 49.79, 49.93, 50.08, 50.08, 50.09, 50.09, 50.1, 51.53, 53.45, 54.8, 56.89, 58.4, 59.77, 61.3, 61.41, 61.46, 61.6, 61.74, 61.89, 62.03, 62.17, 62.32, 62.32]
2024-02-08 22:00:02.816613 INFO pred_bat: EXPORT: [ 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25]
2024-02-08 22:00:02.818497 INFO pred_bat: METRIC: [5920.46, 5938.93, 5942.88, 5957.88, 5972.78, 5987.51, 5988.0, 5988.48, 5989.0, 5989.6, 6211.56, 6572.94, 6788.28, 7076.9, 7273.3, 7446.09, 7641.55, 7657.23, 7662.95, 7681.63, 7703.1, 7722.85, 7740.36, 7757.29, 7773.7, 7773.7]
2024-02-08 22:00:02.994498 INFO pred_bat: Battery has 1.08 hours left - now at 0.3
2024-02-08 22:00:03.025713 INFO pred_bat: predict base10 end_record 02-09 23:05:00 final soc 0.4 kWh metric 7804.26 p metric_keep 917.33 min_soc 0.4 @ 02-08 23:05:00 kWh load 25.06 pv 17.03
2024-02-08 22:00:03.027621 INFO pred_bat: [ 22:00, 23:00, 00:00, 01:00, 02:00, 03:00, 04:00, 05:00, 06:00, 07:00, 08:00, 09:00, 10:00, 11:00, 12:00, 13:00, 14:00, 15:00, 16:00, 17:00, 18:00, 19:00, 20:00, 21:00, 22:00, 23:00]
2024-02-08 22:00:03.029482 INFO pred_bat: SOC: [ 0.3, 0.43, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4, 0.4]
2024-02-08 22:00:03.031470 INFO pred_bat: STATE: [ g<be-, g~be~, g~be~, g~be~, g~be~, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g<be-, g~be+, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~]
2024-02-08 22:00:03.033311 INFO pred_bat: LOAD: [ 11.92, 12.06, 12.14, 12.29, 12.43, 12.58, 12.58, 12.59, 12.59, 12.6, 14.03, 15.97, 17.36, 19.5, 21.06, 22.47, 24.02, 24.15, 24.2, 24.34, 24.48, 24.63, 24.77, 24.92, 25.06, 25.06]
2024-02-08 22:00:03.035145 INFO pred_bat: PV: [ 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.99, 16.99, 17.0, 17.01, 17.02, 17.02, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03]
2024-02-08 22:00:03.037014 INFO pred_bat: IMPORT: [ 49.43, 49.61, 49.67, 49.81, 49.95, 50.1, 50.1, 50.11, 50.11, 50.12, 51.55, 53.49, 54.87, 57.0, 58.55, 59.96, 61.5, 61.63, 61.68, 61.82, 61.96, 62.11, 62.25, 62.4, 62.54, 62.54]
2024-02-08 22:00:03.038881 INFO pred_bat: EXPORT: [ 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25]
2024-02-08 22:00:03.040778 INFO pred_bat: METRIC: [5920.46, 5939.78, 5944.88, 5959.88, 5974.78, 5989.51, 5990.0, 5990.48, 5991.0, 5991.6, 6213.56, 6577.74, 6799.5, 7093.55, 7294.58, 7471.48, 7669.84, 7687.2, 7693.34, 7712.19, 7733.67, 7753.41, 7770.92, 7787.86, 7804.26, 7804.26]
2024-02-08 22:00:03.125083 INFO pred_bat: predict best10 end_record 02-09 23:05:00 final soc 0.6 kWh metric 7517.47 p metric_keep 12.43 min_soc 0.4 @ 02-09 21:35:00 kWh load 25.06 pv 17.03
2024-02-08 22:00:03.127006 INFO pred_bat: [ 22:00, 23:00, 00:00, 01:00, 02:00, 03:00, 04:00, 05:00, 06:00, 07:00, 08:00, 09:00, 10:00, 11:00, 12:00, 13:00, 14:00, 15:00, 16:00, 17:00, 18:00, 19:00, 20:00, 21:00, 22:00, 23:00]
2024-02-08 22:00:03.128860 INFO pred_bat: SOC: [ 0.3, 0.5, 2.92, 3.0, 3.25, 5.25, 7.67, 9.99, 9.99, 9.98, 8.45, 6.07, 4.58, 2.29, 0.65, 3.08, 1.46, 1.32, 1.27, 1.12, 0.96, 0.81, 0.65, 0.5, 0.4, 0.4]
2024-02-08 22:00:03.130653 INFO pred_bat: STATE: [ g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g~be-, g~be-, g~be-, g~be-, g~be-, g~be-, g~be-, g<bf+, g~be-, g~be-, g~be-, g~be+, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~, g<bf+]
2024-02-08 22:00:03.132521 INFO pred_bat: LOAD: [ 11.92, 12.06, 12.14, 12.29, 12.43, 12.58, 12.58, 12.59, 12.59, 12.6, 14.03, 15.97, 17.36, 19.5, 21.06, 22.47, 24.02, 24.15, 24.2, 24.34, 24.48, 24.63, 24.77, 24.92, 25.06, 25.06]
2024-02-08 22:00:03.134381 INFO pred_bat: PV: [ 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.99, 16.99, 17.0, 17.01, 17.02, 17.02, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03, 17.03]
2024-02-08 22:00:03.136330 INFO pred_bat: IMPORT: [ 49.43, 49.79, 52.47, 52.7, 53.11, 55.4, 58.01, 60.51, 60.51, 60.51, 60.51, 60.51, 60.51, 60.51, 60.53, 64.54, 64.58, 64.58, 64.58, 64.58, 64.58, 64.58, 64.58, 64.58, 64.63, 64.63]
2024-02-08 22:00:03.138214 INFO pred_bat: EXPORT: [ 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53, 0.53]
2024-02-08 22:00:03.140393 INFO pred_bat: METRIC: [5920.46, 5958.76, 6208.59, 6231.97, 6274.6, 6507.97, 6769.91, 7019.58, 7019.58, 7019.58, 7019.58, 6977.61, 6977.61, 6977.74, 6980.58, 7485.86, 7491.15, 7491.15, 7491.15, 7491.15, 7491.15, 7491.15, 7491.15, 7491.15, 7497.27, 7497.27]
2024-02-08 22:00:03.226687 INFO pred_bat: predict best end_record 02-09 23:05:00 final soc 0.71 kWh metric 7502.41 p metric_keep 0 min_soc 0.51 @ 02-09 21:35:00 kWh load 25.04 pv 17.24
2024-02-08 22:00:03.228923 INFO pred_bat: [ 22:00, 23:00, 00:00, 01:00, 02:00, 03:00, 04:00, 05:00, 06:00, 07:00, 08:00, 09:00, 10:00, 11:00, 12:00, 13:00, 14:00, 15:00, 16:00, 17:00, 18:00, 19:00, 20:00, 21:00, 22:00, 23:00]
2024-02-08 22:00:03.230900 INFO pred_bat: SOC: [ 0.3, 0.5, 2.92, 3.0, 3.25, 5.25, 7.67, 9.99, 9.99, 9.98, 8.45, 6.07, 4.62, 2.38, 0.77, 3.2, 1.6, 1.48, 1.44, 1.28, 1.13, 0.97, 0.82, 0.66, 0.51, 0.51]
2024-02-08 22:00:03.232733 INFO pred_bat: STATE: [ g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g<bf+, g~be-, g~be-, g~be-, g~be-, g~be-, g~be-, g~be-, g<bf+, g~be-, g~be-, g~be-, g~be+, g~be~, g~be~, g~be~, g~be~, g~be~, g~be~, g<bf+]
2024-02-08 22:00:03.234597 INFO pred_bat: LOAD: [ 11.92, 12.05, 12.12, 12.27, 12.41, 12.56, 12.56, 12.57, 12.57, 12.58, 14.01, 15.95, 17.34, 19.48, 21.04, 22.45, 24.0, 24.13, 24.18, 24.32, 24.46, 24.61, 24.75, 24.9, 25.04, 25.04]
2024-02-08 22:00:03.236474 INFO pred_bat: PV: [ 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 16.98, 17.0, 17.05, 17.1, 17.15, 17.19, 17.22, 17.23, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24, 17.24]
2024-02-08 22:00:03.238365 INFO pred_bat: IMPORT: [ 49.43, 49.78, 52.45, 52.68, 53.09, 55.38, 57.99, 60.49, 60.49, 60.49, 60.49, 60.49, 60.49, 60.49, 60.5, 64.48, 64.52, 64.52, 64.52, 64.52, 64.52, 64.52, 64.52, 64.52, 64.52, 64.52]
2024-02-08 22:00:03.240226 INFO pred_bat: EXPORT: [ 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.25, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54, 0.54]
2024-02-08 22:00:03.242132 INFO pred_bat: METRIC: [5920.46, 5957.36, 6206.52, 6229.9, 6272.53, 6505.9, 6767.84, 7017.51, 7017.51, 7017.51, 7017.51, 6973.69, 6973.69, 6973.69, 6976.02, 7477.19, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21, 7482.21]
2024-02-08 22:00:03.448483 INFO pred_bat: Evaluate trigger {'name': 'large', 'minutes': 60, 'energy': 1.0} results off total_energy 0
2024-02-08 22:00:03.457737 INFO pred_bat: Evaluate trigger {'name': 'small', 'minutes': 15, 'energy': 0.25} results off total_energy 0
2024-02-08 22:00:03.466221 INFO pred_bat: Best charging limit socs [0.5, 3.34, 3.0, 3.25, 5.25, 10.0, 3.61, 10.0, 10.0] export [57] gives import battery 47.21 house 0.06 export 0.54 metric 7502.41 metric10 7517.47
2024-02-08 22:00:03.540049 INFO pred_bat: Export threshold used for optimisation was 172.5p
2024-02-08 22:00:03.595014 INFO pred_bat: High export rate windows [0: 02-08 22:00:00 - 02-08 23:00:00 @ 85.0, 1: 02-09 00:00:00 - 02-09 02:00:00 @ 83.0, 2: 02-09 02:00:00 - 02-09 03:00:00 @ 81.0, 3: 02-09 03:00:00 - 02-09 05:00:00 @ 80.0, 4: 02-09 05:00:00 - 02-09 06:00:00 @ 86.0, 5: 02-09 06:00:00 - 02-09 07:00:00 @ 98.0, 6: 02-09 07:00:00 - 02-09 08:00:00 @ 124.0, 7: 02-09 08:00:00 - 02-09 09:00:00 @ 150.0, 8: 02-09 09:00:00 - 02-09 10:00:00 @ 128.0, 9: 02-09 10:00:00 - 02-09 11:00:00 @ 110.0, 10: 02-09 11:00:00 - 02-09 12:00:00 @ 104.0, 11: 02-09 12:00:00 - 02-09 13:00:00 @ 101.0, 12: 02-09 13:00:00 - 02-09 14:00:00 @ 103.0, 13: 02-09 14:00:00 - 02-09 16:00:00 @ 107.0, 14: 02-09 16:00:00 - 02-09 17:00:00 @ 105.0, 15: 02-09 17:00:00 - 02-09 18:00:00 @ 119.0, 16: 02-09 18:00:00 - 02-09 19:00:00 @ 109.0, 17: 02-09 19:00:00 - 02-09 20:00:00 @ 97.0, 18: 02-09 20:00:00 - 02-09 21:00:00 @ 94.0, 19: 02-09 21:00:00 - 02-09 22:00:00 @ 91.0, 20: 02-09 22:00:00 - 02-09 23:00:00 @ 85.0, 21: 02-10 00:00:00 - 02-10 02:00:00 @ 83.0, 22: 02-10 02:00:00 - 02-10 03:00:00 @ 81.0, 23: 02-10 03:00:00 - 02-10 05:00:00 @ 80.0, 24: 02-10 05:00:00 - 02-10 06:00:00 @ 86.0, 25: 02-10 06:00:00 - 02-10 07:00:00 @ 98.0, 26: 02-10 07:00:00 - 02-10 08:00:00 @ 124.0, 27: 02-10 08:00:00 - 02-10 09:00:00 @ 150.0, 28: 02-10 09:00:00 - 02-10 10:00:00 @ 128.0, 29: 02-10 10:00:00 - 02-10 11:00:00 @ 110.0, 30: 02-10 11:00:00 - 02-10 12:00:00 @ 104.0, 31: 02-10 12:00:00 - 02-10 13:00:00 @ 101.0, 32: 02-10 13:00:00 - 02-10 14:00:00 @ 103.0, 33: 02-10 14:00:00 - 02-10 16:00:00 @ 107.0, 34: 02-10 16:00:00 - 02-10 17:00:00 @ 105.0, 35: 02-10 17:00:00 - 02-10 18:00:00 @ 119.0, 36: 02-10 18:00:00 - 02-10 19:00:00 @ 109.0, 37: 02-10 19:00:00 - 02-10 20:00:00 @ 97.0, 38: 02-10 20:00:00 - 02-10 21:00:00 @ 94.0, 39: 02-10 21:00:00 - 02-10 22:00:00 @ 91.0]
2024-02-08 22:00:03.606216 INFO pred_bat: Import threshold used for optimisation was 138.4p
2024-02-08 22:00:03.663144 INFO pred_bat: Low import rate windows [0: 02-08 22:00:00 - 02-08 23:00:00 @ 106.7, 1: 02-08 23:00:00 - 02-09 00:00:00 @ 93.1, 2: 02-09 00:00:00 - 02-09 01:00:00 @ 104.0, 3: 02-09 01:00:00 - 02-09 02:00:00 @ 103.3, 4: 02-09 02:00:00 - 02-09 03:00:00 @ 101.8, 5: 02-09 03:00:00 - 02-09 05:00:00 @ 100.25, 6: 02-09 05:00:00 - 02-09 06:00:00 @ 107.2, 7: 02-09 06:00:00 - 02-09 07:00:00 @ 122.9, 8: 02-09 07:00:00 - 02-09 08:00:00 @ 155.2, 9: 02-09 09:00:00 - 02-09 10:00:00 @ 160.2, 10: 02-09 10:00:00 - 02-09 11:00:00 @ 138.0, 11: 02-09 11:00:00 - 02-09 12:00:00 @ 129.6, 12: 02-09 12:00:00 - 02-09 13:00:00 @ 126.1, 13: 02-09 13:00:00 - 02-09 14:00:00 @ 128.4, 14: 02-09 14:00:00 - 02-09 15:00:00 @ 133.9, 15: 02-09 15:00:00 - 02-09 16:00:00 @ 133.2, 16: 02-09 16:00:00 - 02-09 17:00:00 @ 131.2, 17: 02-09 17:00:00 - 02-09 18:00:00 @ 148.9, 18: 02-09 18:00:00 - 02-09 19:00:00 @ 136.9, 19: 02-09 19:00:00 - 02-09 20:00:00 @ 121.4, 20: 02-09 20:00:00 - 02-09 21:00:00 @ 117.4, 21: 02-09 21:00:00 - 02-09 22:00:00 @ 113.7, 22: 02-09 22:00:00 - 02-09 23:00:00 @ 106.7, 23: 02-09 23:00:00 - 02-10 00:00:00 @ 93.1, 24: 02-10 00:00:00 - 02-10 01:00:00 @ 104.0, 25: 02-10 01:00:00 - 02-10 02:00:00 @ 103.3, 26: 02-10 02:00:00 - 02-10 03:00:00 @ 101.8, 27: 02-10 03:00:00 - 02-10 05:00:00 @ 100.25, 28: 02-10 05:00:00 - 02-10 06:00:00 @ 107.2, 29: 02-10 06:00:00 - 02-10 07:00:00 @ 122.9, 30: 02-10 07:00:00 - 02-10 08:00:00 @ 155.2, 31: 02-10 09:00:00 - 02-10 10:00:00 @ 160.2, 32: 02-10 10:00:00 - 02-10 11:00:00 @ 138.0, 33: 02-10 11:00:00 - 02-10 12:00:00 @ 129.6, 34: 02-10 12:00:00 - 02-10 13:00:00 @ 126.1, 35: 02-10 13:00:00 - 02-10 14:00:00 @ 128.4, 36: 02-10 14:00:00 - 02-10 15:00:00 @ 133.9, 37: 02-10 15:00:00 - 02-10 16:00:00 @ 133.2, 38: 02-10 16:00:00 - 02-10 17:00:00 @ 131.2, 39: 02-10 17:00:00 - 02-10 18:00:00 @ 148.9, 40: 02-10 18:00:00 - 02-10 19:00:00 @ 136.9, 41: 02-10 19:00:00 - 02-10 20:00:00 @ 121.4, 42: 02-10 20:00:00 - 02-10 21:00:00 @ 117.4, 43: 02-10 21:00:00 - 02-10 22:00:00 @ 113.7]
2024-02-08 22:00:03.670632 INFO pred_bat: Charge window will be: 2024-02-08 22:00:00+01:00 - 2024-02-09 05:00:00+01:00 - current soc 3 target 5
2024-02-08 22:00:03.675651 INFO pred_bat: Inverter 0 Starting charge to 5 % via Service huawei_solar/forcible_charge_soc
2024-02-08 22:00:03.678669 INFO pred_bat: Configuring charge window now (now 02-08 22:00:00 target set_window_minutes 30 charge start time 02-08 22:00:00
2024-02-08 22:00:03.680767 INFO pred_bat: Next discharge window will be: 2024-02-09 08:25:00+01:00 - 2024-02-09 09:01:00+01:00 at reserve 57
2024-02-08 22:00:03.682529 INFO pred_bat: Setting ECO mode as we are not yet within the discharge window - next time is 02-09 08:25:00 - 02-09 09:00:00
2024-02-08 22:00:03.682763 WARNING HASS: Error calling Home Assistant service default/huawei_solar/forcible_charge_soc
2024-02-08 22:00:03.683995 WARNING HASS: Code: 400, error: 400: Bad Request
2024-02-08 22:00:03.686872 INFO pred_bat: Inverter 0 Adjust force discharge to False, change times from 00:00:00 - 00:00:00 to 00:00:00 - 00:00:00
2024-02-08 22:00:03.690658 INFO pred_bat: Inverter 0 Current Target SOC is 5 already at target
2024-02-08 22:00:03.692948 INFO pred_bat: Current SOC 3% is less than Target SOC 5. Grid charging enabled with charge current set to 65.00
2024-02-08 22:00:03.705430 INFO pred_bat: Will not recompute the plan, it is 5.0 minutes old and max age is 10 minutes
2024-02-08 22:00:03.706278 INFO pred_bat: Completed run status Charging